Electric Double Flap Valve Design Manufacturers
- THT
- Tianjin, China
- 25 days
- 2000
Electric Double Flap Valve adopts steel plate welding structure, counterweight bar self reset mechanism, compact structure, stable and reliable operation
The valve plate of the Electric Double Flap Valve automatically opens under the action of material gravity. After the material falls, the counterweight lever system makes the valve plate reset automatically to prevent the wild wind from blowing in, thus completing the material transportation.
Electric Double Flap Valve Design Manufacturers
The Electric Double Flap Valve is widely used in building materials, metallurgy, chemical industry, electric power and other industries.
The Electric Double Flap Valve is used as the discharge device of ash hopper of all kinds of equipment and the feeding and discharging device of various grinding machines, dryers and silos to prevent the wind from blowing in.
Electric Double Flap Valve adopts steel plate welding structure, counterweight bar self reset mechanism, compact structure, stable and reliable operation.
The valve plate of the Electric Double Flap Valve automatically opens under the action of material gravity. After the material falls, the counterweight lever system makes the valve plate reset automatically to prevent the wild wind from blowing in, thus completing the material transportation.
Size | 150*150-800*800 |
Strength test pressure | 0.15mpa |
Suitable medium | Solid particles, dust |
Suitable temperature | ≤250℃ |
Leakage rate | ≤1% |
Discharge capacity | 18m3/h |
1. Use feeler gauge to measure the average clearance of each point ≤ 0.12mm.
2. Adjust the thickness of part No. 13 to ensure the axial fit of the shaft.
3. According to the required pressure of valve plate, adjust the distance of iron distribution on the crank to achieve accurate opening and closing without jamming.
4. After the valve assembly is qualified, rivet the thread of Part 20 to prevent loosening.
5. The non machined surface shall be coated with anti rust primer twice, and then the top coat (gray paint) shall be sprayed twice.
Body | Carbon steel |
disc | Carbon steel |
Heavy hammer | Carbons steel |
Electric actuator |